Skip to main content

Call NiceLabel: 1-888-894-6423

DATAMAX printer drivers

datamax oneil printer capabilities

Supported printers

  • Bidirectional DATAMAX Allegro
  • Bidirectional DATAMAX Allegro 2
  • Bidirectional DATAMAX DMX 400
  • Bidirectional DATAMAX DMX 430
  • Bidirectional DATAMAX DMX 600
  • Bidirectional DATAMAX DMX 800
  • Bidirectional Rfid DATAMAX DMX A-4212
  • Bidirectional Rfid DATAMAX DMX A-4310
  • Bidirectional Rfid DATAMAX DMX A-4408
  • Bidirectional Rfid DATAMAX DMX A-4606
  • Bidirectional Rfid DATAMAX DMX A-6212
  • Bidirectional Rfid DATAMAX DMX A-6310
  • Bidirectional DATAMAX DMX E-3202
  • Bidirectional DATAMAX DMX E-4203
  • Bidirectional DATAMAX DMX E-4204
  • Bidirectional DATAMAX DMX E-4205e Mark II
  • Bidirectional DATAMAX DMX E-4304
  • Bidirectional DATAMAX DMX E-4304e Mark II
  • Bidirectional DATAMAX DMX EX2
  • Bidirectional Rfid DATAMAX DMX H-4212
  • Bidirectional Rfid DATAMAX DMX I-4206
  • Bidirectional Rfid DATAMAX DMX I-4208
  • Bidirectional Rfid DATAMAX DMX I-4210
  • Bidirectional Rfid DATAMAX DMX I-4212
  • Bidirectional Rfid DATAMAX DMX I-4308
  • Bidirectional Rfid DATAMAX DMX I-4406
  • Bidirectional Rfid DATAMAX DMX I-4604
  • Bidirectional DATAMAX DMX M-4206
  • Bidirectional DATAMAX DMX M-4208
  • Bidirectional DATAMAX DMX M-4306
  • Bidirectional DATAMAX DMX ST-3210
  • Bidirectional DATAMAX DMX ST-3306
  • Bidirectional DATAMAX DMX SV-3210
  • Bidirectional DATAMAX DMX SV-3306
  • Bidirectional DATAMAX DMX W-6208
  • Bidirectional DATAMAX DMX W-6308
  • Bidirectional DATAMAX DMX W-8306
  • Bidirectional DATAMAX DMX XL
  • Bidirectional DATAMAX Ovation
  • Bidirectional DATAMAX Ovation 2
  • Bidirectional DATAMAX PE 42
  • Bidirectional DATAMAX PE 43
  • Bidirectional DATAMAX Prodigy
  • Bidirectional DATAMAX Prodigy MAX 200
  • Bidirectional DATAMAX Prodigy MAX 300
  • Bidirectional DATAMAX Prodigy Plus
  • Bidirectional DATAMAX Titan
  • Bidirectional DATAMAX Compact4
  • Bidirectional DATAMAX Compact4 300DPI
  • Bidirectional DATAMAX Compact4 Mark II
  • Bidirectional DATAMAX Compact4 Mark II 300DPI
  • Bidirectional DATAMAX Compact4 Mobile
  • Bidirectional DATAMAX Compact4 Mobile 300DPI
  • Bidirectional DATAMAX Compact4 Mobile Mark II
  • Bidirectional DATAMAX Compact4 Mobile Mark II 300DPI
  • Bidirectional Rfid DATAMAX DMX H-4212X
  • Bidirectional Rfid DATAMAX DMX H-4310
  • Bidirectional Rfid DATAMAX DMX H-4310X
  • Bidirectional Rfid DATAMAX DMX H-4408
  • Bidirectional Rfid DATAMAX DMX H-4606
  • Bidirectional Rfid DATAMAX DMX H-4606X
  • Bidirectional Rfid DATAMAX DMX H-6210
  • Bidirectional Rfid DATAMAX DMX H-6212X
  • Bidirectional Rfid DATAMAX DMX H-6308
  • Bidirectional Rfid DATAMAX DMX H-6310X
  • Bidirectional Rfid DATAMAX DMX H-8308X
  • Bidirectional Rfid DATAMAX DMX M-4206 Mark II
  • Bidirectional Rfid DATAMAX DMX M-4210 Mark II
  • Bidirectional Rfid DATAMAX DMX M-4308 Mark II
  • Bidirectional DATAMAX Nova4
  • Bidirectional DATAMAX Nova4 300DPI
  • Bidirectional DATAMAX Nova4 TT
  • Bidirectional DATAMAX Nova4 TT 300DPI
  • Bidirectional DATAMAX Nova6
  • Bidirectional DATAMAX Nova6 TT
  • Bidirectional DATAMAX Nova8
  • Bidirectional Datamax O'Neil E4204B Mark III
  • Bidirectional Datamax O'Neil E4205A Mark III
  • Bidirectional Datamax O'Neil E4206L Mark III
  • Bidirectional Datamax O'Neil E4206P Mark III
  • Bidirectional Datamax O'Neil E4304B Mark III
  • Bidirectional Datamax O'Neil E4305A Mark III
  • Bidirectional Datamax O'Neil E4305L Mark III
  • Bidirectional Datamax O'Neil E4305P Mark III
  • Bidirectional Rfid Datamax O'Neil I-4212e Mark II
  • Bidirectional Rfid Datamax O'Neil I-4310e Mark II
  • Bidirectional Rfid Datamax O'Neil I-4606e Mark II
  • Datamax O'Neil p1115
  • Datamax O'Neil p1115s
  • Datamax O'Neil p1120n
  • Datamax O'Neil p1125
  • Datamax O'Neil p1725
  • Bidirectional Datamax O'Neil RL4
  • Datamax O'Neil w1110
Legend:
Title Data
Bidirectional The printer model supports bidirectional communication. NiceLabel driver can obtain the feedback of the printer status. The status can be reported to and displayed in NiceLabel software.
Rfid This printer supports RFID. You can program the RFID tags embedded into the smart label.
Drivers package details
Title Data
Latest version:
Date changed:
5.1.07
September 9, 2014
NiceLabel drivers are tested and work on: Windows Vista, Windows 7, Windows 8, Windows 8.1, Windows Server 2003, Windows Server 2008, Windows Server 2008 R2, Windows Server 2012, Windows Server 2012 R2
Old operating system: NiceLabel printer drivers are no longer tested on Windows XP.
Download drivers form

Download Driver

The package contains 32-bit and 64-bit drivers.

Download Now

Release notes

Sowftware latest release notes
Release version Release description
Ver.: 5.1.07.5339 Datamax Performance series printers did not print corretly multiple pages. This is corrected now.
Ver.: 5.1.07.5327 Element positioning in landscape orientation on ST printer models has been corrected.
Ver.: 5.1.07.5312 Datamax O'neil Performance Series printers (p115, p115s, p1120n, p1125, p1725) prints head first (not bottom first). Print preview picture in the driver is changed accordingly.
Ver.: 5.1.07.5289 New RTC format is supported (YYJJJ: year in two digits + julian date)
Ver.: 5.1.07.5277 Changed texts in about dialogue to better fit in assigned areas.
Ver.: 5.1.07.5226 Imaje printers (Label point programming language) supports now also Julian date in 3 digit format as internal command.
Ver.: 5.1.07.5213 Datamax printer models with support of EPC Class1 (64-bit and 96-bit), from now on support also EPC Class1 512-bit tags.
Ver.: 5.1.07.5141 Interleaved 2 of 5 barcode is now printed correctly
Ver.: 5.1.07.5086 Datamax O'neil performance printers did not send quantity value for every page. This is corrected now.
Ver.: 5.1.07.4926 Printer Install Wizard supports silent installation of Port Monitor modules.
Ver.: 5.1.06.4884 Label Width value is now correct also in landscape orientation. Before the correction height value was set for width in landscape.
Ver.: 5.1.06.4865 Fixed issue with TCP/IP port monitor causing Spooler to report unnecessary errors for longer prints causing delays in data sending
Ver.: 5.1.06.4838 Datamax O'Neil Performance Series printer models are supported now:
Datamax O'Neil p1115
Datamax O'Neil p1115s
Datamax O'Neil p1120n
Datamax O'Neil p1125
Datamax O'Neil p1725
Datamax O'Neil w1110

All Performace printer models have by default "Use printer settings" enabled.

Ver.: 5.1.06.4822

Implemented support for export to SAP. Printer driver was updated to support the latest printer language extensions which enable correct ITF file generation.

Ver.: 5.1.06.4818 New languages supported are: Danish, Hebrew, Slovak and Portuguese (Brazil). Portuguese language is removed.
Ver.: 5.1.06.4815 Language monitor will now retry sending data to printer 3 times before reporting an error to spooler
Ver.: 5.1.06.4800

PrnInst utility quits driver installation if user doesn't trust the publisher.

Ver.: 5.1.05.4788 Driver settings are now correctly updated after being imported.
Ver.: 5.1.03.4633 Help file was updated with a note that some applications can lock the driver and prevent it from being updated by a new version.
Ver.: 5.1.03.4606 Fixed issue with incomplete printout on E printer models.
Ver.: 5.1.02.4507 Fixed custom stocks selection in driver dialog: driver now correctly selects stock. This only applies to drivers version 5.1.02.4378.
Ver.: 5.1.02.4472

On Windows 8 and Windows Server 2012 users were not able to change language settings. Now they can change language settings if they have administrative rights.

Ver.: 5.1.02.4378 Microsoft Access was reporting wrong paper names when custom stocks are defined in driver. Now it works OK.
Ver.: 5.1.02.4371

After leaving an edit field the values in it are now correctly checked according to their specified minimum/maximum values and displayed in correct format for the selected measurement unit.

Ver.: 5.1.01 4402 Add a line stating the requirements needed for asian fonts to be printed correctly by the driver.
Ver.: 5.1.01.4393 Datamax O'Neil E4305L Mark III and Datamax O'Neil E4206L Mark III are supported now.
Ver.: 5.1.01.4360

Prevent occasional labeling software crash when loading labels created with NiceLabel drivers older than version 4.6.16.

Ver.: 5.1.00.4354 Cutter functionality corrected for printing from Windows applications and cutter set to cut every n labels.
Ver.: 5.1.00.4320 If user selects RFID zero padding option on advanced setup dialog on DPL printers, RFID blocks that are not full will be zero padded.
Ver.: 5.1.00.4306 Solved problem with multi-thread printing (sometimes the stream is not correct).
Ver.: 5.0.03.4248 USB memory module added when using "export to printer" on following models: E4206P Mark III, E4305P Mark III, I-4212e Mark II, I-4310e Mark II and I-4606e Mark II.
USB memory module H and USB memory module I available when using "export to printer" on A-Class models, H-Class models, M-4210 Mark II and M-4308 Mark II.
Ver.: 5.0.03.4192 QR barcode is supported on DPL printers.
Prefix and suffix enabled for counters.
Ver.: 5.0.03.4186 User can export label format to A-Class printers on three different locations:RAM, FLASH and now also to SDIO memory slot.
Ver.: 5.0.03.4186 When sending label format to the printer also label width information is included for Datamax printers with LCD. This prevents missing data if label width is not set correctly on the printer.
Label width information is send for printers: A-Class, I-Class, H-Class and M-CLass Mark II (old M-Class are without display).
Ver.: 5.0.03.4183 Date offset is now supported on RTC for DPL printers. Offset is set in days.
The limitation is one RTC variable with offset on the label.
Offset does not work with time variable because of printer firmware limitation.
Ver.: 5.0.02.4141

Darkness now ranges from -20 to 20 instead of -10 to 10

Ver.: 5.0.00.4197 Driver help for barcode font "y dimension" updated.
Ver.: 5.0.00.3897

All the drivers are now digitaly signed to allow installation on Windows 8.

Ver.: 4.6.78.3840 In some rare cases driver crashed when printing a Code128 barcode. This is corrected now.
Ver.: 4.6.76.3790 Fixed occasional Spooler crash when printing Word document with very long filename.
Ver.: 4.6.76.3782

Advanced Port monitor can now be added by using Windows Add New Port Type option.

Ver.: 4.6.76.3763

Port monitor now reconnectes to printer after lost connection

Ver.: 4.6.74.3714

Numeric GS1Databar barcode types no longer have data size requirements

Ver.: 4.6.72.3647

German translation for Tear Off Distance was Abrißabstand, which was wrong. We corrected this translation to Abrisskante.

Ver.: 4.6.69.3612

Driver update didn't preserve settings for all installed printers. This is fixed now.

Ver.: 4.6.69.3581

DPL Vector fonts (CG Times, CG Triumvirate) printed from other Windows applications and not from labeling software were positioned wrong. This is corrected now.

Ver.: 4.6.66.3658 In some case of printing big graphics (color on 64-bit OS for example) the graphic elements could be missing. This is corrected now.
Ver.: 4.6.66.3454

Following models added to distribution: Datamax O'Neil I-4212e Mark II, Datamax O'Neil I-4310e Mark II and Datamax O'Neil I-4606e Mark II.

Ver.: 4.6.66.3436 Obsolete monitor.inf files were removed from drivers that still had them
Ver.: 4.6.66.3392 Removed warning message for special ports, when installing printer driver with Printer Installation Wizard.

If connected to standard Windows TCP/IP port then show warning message.
Ver.: 4.6.66.3390 Datamax E-series Mark III are center oriented printers, but the printer itself calculate the coordinate and the driver does not need to calculate the printing offset.
The same offset is not calculated also for Datamax RL4 printer.
Ver.: 4.6.65.3360

Printer error detailes were missing while printing. The status reporting issue was limited to NicePrintQueue, Enterprise Print Manager(EPM) and NiceLabel.


Ver.: 4.6.65.3334

Additional data was encoded into QR barcode data field. This is corrected now.

Ver.: 4.6.64.3290 Advanced TCP/IP port monitor now supports connections to names as well as IP addresses.
Ver.: 4.6.63.3224

Rotation option on userinterface and QR and MicroQR barcode font rotation now work correctly

Ver.: 4.6.62.3220 RFID added to A-Class printers.
Ver.: 4.6.62.3190 Spooler crash when changing printer port while printing was fixed.
Ver.: 4.6.62.3156 Custom settings for unprintable now work correctly
Ver.: 4.6.60.3059

New printer models added to distribution:
Datamax-ONeil E4204B Mark III, Datamax-ONeil E4304B Mark III, Datamax-ONeil E4205A Mark III, Datamax-ONeil E4305A Mark III, Datamax-ONeil E4206P Mark III, Datamax-ONeil E4305P Mark III and RL4.

Ver.: 4.6.59.3002 Printer ports are now properly shown in Options dialog.
Ver.: 4.6.59.2995 Changed font for Chinese Windows to SimHei.
Ver.: 4.6.52.2829 In old driver peel and dispense option didn't work if label present sensor check box wasn't checked. This is corrected now. If user selects peel or dispense, label present sensor check box is automatically checked.
Ver.: 4.6.51.2800 Czech, Lithuanian and Ukrainian languages are now supported also in all NiceDrivers.

Ver.: 4.6.50.2773 When printing from standard Windows application (like Microsoft Word) and using page rotation (Landscape and/or rotate 180), positions of graphic were shifted relative to internal elements.
Shift size depends on page dimensions, shift direction depends on rotation.
Ver.: 4.6.49.2747

PrnInst utility was updated so that long INF file structure is supported.

Ver.: 4.6.49.2611 When trying to preinstall drivers on Windows 7, user got an "Environment incorrect" error message. This is corrected now.
Ver.: 4.6.48.2718 Cut on last element is available only if no sensor is selected.
Ver.: 4.6.48.2709 Imaje Compact 4 printers support now also DPL (Datamax Programming Language) and they are supported also in NiceDrivers.
New models added to distribution: DATAMAX Compact4 Mark II, DATAMAX Compact4 Mark II 300DPI, DATAMAX Compact4 Mobile Mark II and DATAMAX Compact4 Mobile Mark II 300DPI.
Ver.: 4.6.48.2709 If user selected batch cut (cut at the end) the printout was not OK. This has been corrected and it looks the command for cycle cutter did not work correctly: Because of that it has been removed.
Ver.: 4.6.43.2459 Datamax E-4205e Mark II and E-4304e Mark II printer models are supported.
Ver.: 4.6.43.2445

User is now able to change administrator settings without reopening driver properties dialog as an elevated user. A click on the shielded button and entering the credentials is all that is needed.

Ver.: 4.6.42.2390 All I-Class printers except I-4206 and I-4208 now support also G memory slot which is internal FLASH. Also memory slots correction for SV-3210 and SV-3306 models.
Ver.: 4.6.41.2364 Fixed occasional driver crash when printing extremely large graphics
Ver.: 4.6.41.2361 Page preview icons in "Advanced Dialog" corrected.
Ver.: 4.6.37.2258 Uninstall of printer with Printer Install Wizard did not work on Windows 2003 (x64) system
Ver.: 4.6.34.2269 Time format hh:mm:ss is not supported.
Ver.: 4.6.30.2177 PnP ID numbers have been corrected in a way that LPTENUM and USBPRINT PnP ID is described just once in Datamax.inf file for each printer model.
Ver.: 4.6.30.2157 Media Type selection enabled on printers without display and disabled on printers with display.
Ver.: 4.6.22

Build number is now part of version information in About dialog

Ver.: 4.6.14 DPL printers have ability to print inverse text. This option is supported now also in NiceDrivers.
Ver.: 4.6.14 Macros 05 and 06 on Datamatrix are now supported on printer models with ZPL and DPL printer language.
Ver.: 4.6.14 DPL printer will print unlimited labels quantity with quantity command  of 9999.
Ver.: 4.6.05 When using variables (counters + prompt variables), counters should be numbered separately with ID1..10.
Ver.: 4.6.04 Printing internal Maxicode and PDF-417 now works.
Ver.: 4.6.04

The internal date/time fields could only be used with the internal fonts Datamax1 and Datamax2. When you used any other internal font (including CG Times), the internal date/time didn't get printed. This is corrected now.

Ver.: 4.6.04 WYSIWYG for internal fonts is corrected for DPL printers.
Ver.: 4.6.04 Counter definition should not be present when exporting to SAP (*pnl and *itf file). Of course just in case that counter is not used on the label format.
Ver.: 4.6.01 Postnet barcodes has wrong expansions and are printed too big. This is corrected now and WYSIWYG is OK.
Ver.: 4.6.01 Added Rotation to parsed text in command fonts
Ver.: 4.6.00 Printing process was stopped during heavy duty printing.
Ver.: 4.6.00 Barcode height is corrected for non-203 dpi printers.
Ver.: 4.5.42 Driver print speed optimization
Ver.: 4.5.40

DMX M-4308 Mark II models has problems with positioning of elements on the label. This is corrected now.

Ver.: 4.5.39 PrnInst showed login window, even if the user running the application was administrator.
Ver.: 4.5.37

PrnInst can now be moved to any position (second monitor) and it will stay there. It will not jump back to its original position.

Ver.: 4.5.34 Postnet barcode fonts can no longer have their width changed.
Ver.: 4.5.31 USB PnP Id's added to Datamax printers. For printers DMX ST-3210 and DMX SV-3210 it was only corrected.
Ver.: 4.5.13 If user tryed to print label with large graphics on Mark II models, there was a chance that printer run out of memory.
Ver.: 4.5.12 User can select Automatic or Manual options for Job removing using keyboard in Printer Install Wizard
Ver.: 4.5.12 Fixed labeling software crash when turning off "Use Advanced printer driver interface".
Ver.: 4.5.11 Printer Install Wizard uninstallation of driver doesn`t remove all of the files from the SYSTEM32\spool\drivers\w32x86\3\ folder.
Ver.: 4.5.10 Following printers added: Compact4, Compact4 300DPI, Compact4 Mobile, Compact4 Mobile 300DPI, Nova4, Nova4 300DPI, Nova4 TT, Nova4 TT 300DPI, Nova6, Nova6 TT, Nova8
Ver.: 4.5.09 Following printers added: Compact4, Compact4 300DPI, Compact4 Mobile, Compact4 Mobile 300DPI, Nova4, Nova4 300DPI, Nova4 TT, Nova4 TT 300DPI, Nova6, Nova6 TT, Nova8
Ver.: 4.5.09 Electonic Article Survailance was always disabled on Rfid printers
Ver.: 4.5.09 Fixed printing of Datamatrix and QR barcode font with more then 255 character data
Ver.: 4.5.09 Added automatic termination character for Maxicode barcode font data
Ver.: 4.5.07

Added support for custom printer name after silently installing a printer driver from command line (/INSTPRN; /INSTMULTPRN)

Ver.: 4.5.06 Printer Installation Wizard will be able to automaticly remove all jobs when updating printer
Ver.: 4.5.05 Printer Install Wizard can start an application specified in the command line, after it closes.
Ver.: 4.5.04 Fixed Advanced TCP/IP port to handle leading 0 in IP.
Ver.: 4.5.03 Status monitor is able to detect port conflicts, when two printer drivers are using the same port for bidirectional communication with the printer.
Also when user will delete or install a new printer to the system, Status Monitor will detect the change by itself.
Ver.: 4.5.03 When you disable the option "Use advanced printer driver interface" (in File -> Label Setup -> Printing tab) labeling software will crash with the error "GDI Failure, OK to continue?"
Ver.: 4.5.02 PrnInst didn't set printer attributes correctly. This is fixed now.
Ver.: 4.5.01 Turkish language added
Ver.: 4.5.00  - write MMF to alternative location (research)
 - update MemMaster to store files to this location
 - update driver to read from new location (make sure that the update will be backward compatible)
Ver.: 4.5.00

New setting Printer default. If set, then printer will not send some settings from Options and Advanced Setup tab. This feature is useful for printers with LCD display where user would like to set printer parameters (speed, darkness...) manually.

Ver.: 4.4.73 Uninstall of driver package failed when running a 64bti system.
Ver.: 4.4.69 - RLE graphics compression is added
- inline graphics
- binary transfer
Ver.: 4.4.69 Checkbox "Enable bidirectional support" (Printer properties -> Ports) can now be unchecked automatically during driver installation, corresponding to the flag "Bidirectional" in .inf file.
Bidirectional=0  =>  checkbox is unchecked.
Bidirectional=1  =>  checkbox is checked.
If this information is ommited, Bidirectional=1 is assumed.
Ver.: 4.4.69 Labelling software can now recall variables with more than 31 characters of data.
Ver.: 4.4.69

When you click on the Help button in About dialog help is opened, but it is not linked to any page.

Ver.: 4.4.69 Help on About dialog opens help page with contents 'This program cannot display the webpage'.
Ver.: 4.4.66 New dot positioning is implemented. User is able to change between new (in dots) and existing (1/10 mm) positioning with command y22.
Ver.: 4.4.65 Export label to printer works now correctly also for prompted variables,
Ver.: 4.4.64

Removed Help button as no help is available.

Ver.: 4.4.64 Export to printer didn't work properly. There was a wrong slot number in the exported print stream.
Ver.: 4.4.64 New Japanese translation for Printer Install Wizard
Ver.: 4.4.63 Downloaded fonts allways print in the same size, even if you resize them.
Ver.: 4.4.63 DL of graphics on LPT port doesnt work correctly, when printing you get an empty screen
Ver.: 4.4.63 When user starts Printer Install Wizard the application is shown but without focus
Ver.: 4.4.63

Changed default number for cutting to 1 label instead of 0.

Ver.: 4.4.60 Changed file info for Printer Install Wizard
Ver.: 4.4.60
Two new printers added:
M-4206 Mark II
M-4210 Mark II
Ver.: 4.4.60 Default value for Always use default settings is not correct when instaling it the driver with a configuration file attached.
Ver.: 4.4.52

DLL files for user interface translation did not include version info data.

Ver.: 4.4.52
Ver.: 4.4.52

Labels transfered from different systems now retain their driver settings.

Ver.: 4.4.52 When using printer template export in File->Export menu of labelling application you get the following error: "An error occured during printer template export".
This problem applies to EasyPlug and Labelpoint printers, templates that use "Variables" field and labels with variable Unicode fonts.
Ver.: 4.4.51
Increased lenght for filename and path in import and export of settings.
Ver.: 4.4.51
POSTNET barcodes have a fixed height and width, but the interface allows the user to change these dimensions. 
Ver.: 4.4.50 Import and export didn't work if filename and path exceeded the length of 80 characters while windows support 256 character lengths
Ver.: 4.4.50 Click on "Stocks" panel caused error if stock list was empty. This is fixed now.
Ver.: 4.4.30 - support for preinstall on all supported platforms
Ver.: 4.4.01
Store/Recall funcionality corrected for M-Class printers.
Ver.: 4.4.01 EndDocument escape was sent even when there was no StartDocument.
Ver.: 4.4.01
If driver gets no separator character description for decimal number from the OS, driver puts a "+" or "," string as default character. The result was seen for page size (example)
Now the dot character "." is set for default separator in this case.
Ver.: 4.4.00 Invalid stocks are now marked. User can open the Stock properties dialog and press OK to fix the problem (which is usually stock dimension). Stock size will be automatically adjusted.
Ver.: 4.4.00 UI for commands fonts works now properly also in Japanese language.
Ver.: 4.4.00 In some rare cases streams sent to the printer had an extra "0" added in it.
Ver.: 4.3.73 There was a bug found on barcode SSCC18 (EAN/UCC128, Code128), because in case of string "338386009002153746" two bytes "02" in the middle of the data stream causes printing character " (colon). This is corrected now.
Ver.: 4.3.72 Sometimes a print stream is not send to the printer, and it stays stuck in the spooler
Ver.: 4.3.71 Media type selection (Properties>Advanced setup>Other) has been added some time ago for all Datamax printers. But we have found some problems with this option for some printer models with display on printer's control panel. The problem is that printer resets itself when gets the command "KcXXX", so this option has been disabled for I-Class and W-Class printers.
Ver.: 4.3.70 Media type selection (direct thermal, thermal transfer) is added into Datamax advanced setup dialog. User will find this option in secondary dialog which can be opened by button "Other".
Ver.: 4.3.63 Port monitor crashed when setting up port details (IP and port number)
Ver.: 4.3.60 "Layout outside label" is no longer treated as an error. It will only show up as a warning.
Ver.: 4.3.60 Barcode fonts vanished instead of being imported.
Ver.: 4.3.59 Driver didn't handl RSS unprintable character encoding
Ver.: 4.3.59 Microsoft Vista operating system is not mentioned in the text file that is distributed with the driver.
Ver.: 4.3.59 Stocks were not imported if user didn't view the stocks dialog beforehand
Ver.: 4.3.56 Barcode ratio values are not shown in Barcode Fonts dialog. This only happens when you are editing existing barcode font.
Ver.: 4.3.55 10 new Datamax printer models are supported: DMX H-4212 DMX H-4408 DMX H-4310 DMX H-4606 DMX H-6210 DMX H-6308 DMX H-4606X DMX H-6212X DMX H-6310X DMX H-8308X
Ver.: 4.3.55 Spooler crashed during the installation, if there were any printers allready installed on the system.
Ver.: 4.3.54 While installing a printer driver on certain systems the spooler crashed.
Ver.: 4.3.54 "delete" button was enabled even if the barcode/command fonts list was empty. This is fixed now.
Ver.: 4.3.54 Export of barcode fonts didn't work properly unless user clicked on barcode fonts tab before exporting them. This is fixed now.
Ver.: 4.3.54 Increased timeouts for better printer status response times
Ver.: 4.3.54 Slow printing occurred when a Not Accessible printer was found on a network. Printer status was also not received immediately.
Ver.: 4.3.53 Some printers have built in web server (for setup purposes) and labeling application can now display this information.
Ver.: 4.3.53 Nonprintable characters (characters below ASCII 32 like , , ) in barcodes are not correctly encoded for Labelpoint printers.
Ver.: 4.3.53 Status for printers (that use bidirectionaal communication) was not correct when the printer was not physicaly connected to the computer. Status was changing between Not Accessible and Ready
Ver.: 4.3.51 Driver can now override the default document settings of some applications with driver default settings (set up in printer spooler)
Ver.: 4.3.07 Printer default value can be used for X and Y position offset for printers with Labelpoint printer language.
Ver.: 4.3.07 After viewing the Help file CHM file was locked and because of that reboot was needed to complete the installation. New version of driver will not lock the CHM any more and because of that reboot is not needed.
Ver.: 4.3.06 Barcode fonts and command fonts are now stored in registry.
Ver.: 4.3.06 Printing did not work on nonbidirectional printers. Printer Error was displayed the whole time
Ver.: 4.3.05 Printing did not work when bidirectional was enabled
Ver.: 4.3.04 New Port monitor is added to the distribution
Ver.: 4.3.04 On Windows Vista there is warning displayed if user doesn't have appropriate permissions to create (or write to) certain driver files.
Ver.: 4.3.04 Old HLP help file format was exchanged for new CHM file format.
Ver.: 4.3.04 Settings section on Advanced dialog changed.
Ver.: 4.3.04 When user changed printer's port, the printing was no longer possible until reboot.
Ver.: 4.3.04 Port monitor now uses correct (64 bit) interface file on 64bit systems.
Ver.: 4.3.04 Installation did not go through when upgrading from old printer driver, if the user had the driver connected to the Advanced Port Monitor (LAN)
Ver.: 4.3.04 Bug fixed, where some changes on stocks updated default umprintable area values.
Ver.: 4.3.03 Spooler crashed, if user had multiple bidirectional printers using the same port, while using a status monitoring application
Ver.: 4.3.02 Stocks were not imported properly or were not shown immediately after import.
Ver.: 4.3.01 Korean language added.
Ver.: 4.3.01 Darkness and speed settings are ignored for Labelpoint printers.
Ver.: 4.3.01 Driver does not show all stocks in 'Stocks' combo box on 'Options' dialog. Missing stocks have heights that are near the maximum printer's limit.
Ver.: 4.3.00 Changed window handling so that port monitor setup windows can appear on Vista
&gt&gt See more release notes

Go back to top

This site uses cookies. By continuing to browse the site you are agreeing to our use of cookies. Find out more here X

Proven and trusted by the world's greatest companies

Enterprise label printing solutions
NiceLabel eterprise label printing solutions